Operating Limits
Typical Operating Pressure | 750 – 950 psi (5,175 – 6,555 kPa) |
Maximum Operating Pressure | 1,200 psi (8,275 kPa) |
Maximum Operating Temperature | 113°F (45°C) |
Maximum Cleaning Temperature | 113°F (45°C) |
Maximum Continuous Free Chlorine | <0.1 mg/l |
Allowable pH – Continuous Operation | 4 – 11 |
Allowable pH – Short Term Cleaning | 2.5 – 11 |
Maximum Differential Pressure Per Element | 10 psi (69 kPa) |
Maximum Differential Pressure Per Vessel | 60 psi (414 kPa) |
Maximum Feed Turbidity | 1 NTU |
Maximum Feed SDI (15 minute test) | 5 |
Remarks
Proper start-up of reverse osmosis water treatment systems is essential to prepare the membranes for operating service and to prevent membrane damage due to overfeeding or hydraulic shock. Following the proper start-up sequence also helps ensure that system operating parameters conform to design specifications so that system water quality and productivity goals can be achieved.
Before initiating system start-up procedures, membrane pretreatment, loading of the membrane elements, instrument calibration and other system checks should be completed.
Request for catalog or technical support, please click here.
Reviews
There are no reviews yet.